{"id":19923,"date":"2022-08-14T06:11:46","date_gmt":"2022-08-14T06:11:46","guid":{"rendered":"https:\/\/mdr.foobrdigital.com\/?p=6350"},"modified":"2022-08-14T06:11:46","modified_gmt":"2022-08-14T06:11:46","slug":"pulley-belt-calculations","status":"publish","type":"post","link":"https:\/\/mudassirbackup.infinitycodestudio.com\/index.php\/2022\/08\/14\/pulley-belt-calculations\/","title":{"rendered":"Pulley Belt Calculations"},"content":{"rendered":"\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" src=\"https:\/\/mdr.foobrdigital.com\/wp-content\/uploads\/2022\/08\/image-60.png\" alt=\"\" class=\"wp-image-6351\"\/><\/figure>\n\n\n\n<p>As shown in the image below, an\u00a0induction motor\u00a0is connected via a belt to drive two pulleys which will move centrifugal fan. This is this fairly typical of what you might find to in an\u00a0Air Handling Unit or AHU.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/theengineeringmindset.com\/wp-content\/uploads\/2019\/05\/Pulley-belt-fan-AHU.png\" alt=\"\" class=\"wp-image-2936\"\/><\/figure>\n\n\n\n<p>You\u2019d also have this set up on some pumps and also some conveyor belts.<\/p>\n\n\n\n<p>The two things we\u2019ll be calculating in this video are the belt length (how long is, or does that need to be?) And also the distance between the two pulleys, which we\u2019re just going to reverse that calculation to find that.<\/p>\n\n\n\n<p>These calculations are mainly for existing installations but you could also put it towards your design if you want to calculate what the length needs to be of the belt, as long as you already know the distance between the two pulleys and the size of the pulleys. The second part, the distance between the pulleys, is if you already know what length belt you need and also you know the diameter of both the pulleys. But you\u2019re not sure exactly what the distance should be between them.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Calculate Pulley Belt Length<\/h2>\n\n\n\n<p>I just want to point out that these calculations may vary slightly from the real world scenario, but this is the best calculation that you can perform to get the most accurate figure.<\/p>\n\n\n\n<p>First of all, we\u2019ll have a look at what length dose the pulley belt need to be? In this example, we\u2019re going to look at the belt between the induction motor and also a centrifugal fan in an AHU.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" src=\"https:\/\/mdr.foobrdigital.com\/wp-content\/uploads\/2022\/08\/333333.jpg\" alt=\"\" class=\"wp-image-6356\"\/><figcaption>Dimensions known to calculate belt length<\/figcaption><\/figure>\n\n\n\n<p>Now, we already know the size of the pulley, either from the manufacturer\u2019s data or we can go out into the building and actually measure this. Remember Pulley 1 is always going to be the largest pulley you have, and you\u2019ll see this as we go through the calculations shortly.<\/p>\n\n\n\n<p>We also have Pulley 2 and we know the diameter of this pulley as well. Again, this is taken from manufacturer\u2019s data or measured. We also know the centre distance between these two pulleys.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/theengineeringmindset.com\/wp-content\/uploads\/2019\/05\/Pulley-belt-calculation-formula-1024x68.png\" alt=\"\" class=\"wp-image-2938\"\/><\/figure>\n\n\n\n<p>The image above shows the formula we\u2019re going to use to calculate this. It looks quite long but it\u2019s not as complex as it might first seem. I\u2019ve also colour coded the numbers, as many as possible, just to make it a little bit easier. And I\u2019ve also split the calculations into metric and imperial. So whichever units of measurement you\u2019re using, you can follow these through.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" src=\"https:\/\/mdr.foobrdigital.com\/wp-content\/uploads\/2022\/08\/112222222.jpg\" alt=\"\" class=\"wp-image-6355\"\/><\/figure>\n\n\n\n<p>We can now drop our numbers in. Remember we calculate the brackets first.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Calculate distance between pulleys<\/h2>\n\n\n\n<p>If we need to calculate the distance between the centres of the two pulleys, then we can use the following calculations to approximate this. We will need to know the diameters of the pulleys as well as the belt length.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" src=\"https:\/\/mdr.foobrdigital.com\/wp-content\/uploads\/2022\/08\/Pulley-distance-calculation.png\" alt=\"\" class=\"wp-image-6354\"\/><figcaption>Dimensions known for pulley distance calculation<\/figcaption><\/figure>\n\n\n\n<p>The above image illustrates which dimensions we need and each is colour coded to half make it a little easier.<\/p>\n\n\n\n<p>If you are using the&nbsp;<strong>metric system<\/strong>, then you can use the following calculations.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/theengineeringmindset.com\/wp-content\/uploads\/2019\/05\/Formula-for-pulley-distance-calculation-1024x59.png\" alt=\"\" class=\"wp-image-2942\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" src=\"https:\/\/mdr.foobrdigital.com\/wp-content\/uploads\/2022\/08\/222.png\" alt=\"\" class=\"wp-image-6353\"\/><figcaption>Pulley distance calculation&nbsp;<strong>METRIC<\/strong><\/figcaption><\/figure>\n\n\n\n<p>If you\u2019re using the&nbsp;<strong>imperial system<\/strong>, then you can use the following calculations<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" src=\"https:\/\/mdr.foobrdigital.com\/wp-content\/uploads\/2022\/08\/12-1.png\" alt=\"\" class=\"wp-image-6352\"\/><figcaption>Pulley distance calculation&nbsp;<strong>IMPERIAL<\/strong><\/figcaption><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>As shown in the image below, an\u00a0induction motor\u00a0is connected via a belt to drive two pulleys which will move centrifugal fan. This is this fairly typical of what you might find to in an\u00a0Air Handling Unit or AHU. You\u2019d also have this set up on some pumps and also some conveyor belts. The two things [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[359],"tags":[],"_links":{"self":[{"href":"https:\/\/mudassirbackup.infinitycodestudio.com\/index.php\/wp-json\/wp\/v2\/posts\/19923"}],"collection":[{"href":"https:\/\/mudassirbackup.infinitycodestudio.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/mudassirbackup.infinitycodestudio.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/mudassirbackup.infinitycodestudio.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/mudassirbackup.infinitycodestudio.com\/index.php\/wp-json\/wp\/v2\/comments?post=19923"}],"version-history":[{"count":0,"href":"https:\/\/mudassirbackup.infinitycodestudio.com\/index.php\/wp-json\/wp\/v2\/posts\/19923\/revisions"}],"wp:attachment":[{"href":"https:\/\/mudassirbackup.infinitycodestudio.com\/index.php\/wp-json\/wp\/v2\/media?parent=19923"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/mudassirbackup.infinitycodestudio.com\/index.php\/wp-json\/wp\/v2\/categories?post=19923"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/mudassirbackup.infinitycodestudio.com\/index.php\/wp-json\/wp\/v2\/tags?post=19923"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}